TESLACOIL VENTURES™v1.0 • OFF-GRID

Autonomy Clock

Transparent, data-verifiable off-grid runtime for utilities, microgrids, and sustainability-driven enterprises.

VERIFIED CALCULATION

SYSTEM CONFIGURATION

Battery Capacity
kWh
102000
Average Load
kW
1500
Average continuous load during island
Solar Input Avg
kW
0500
Average solar production during island. 0 = night scenario
Depth of Discharge
%
50100
Li-ion = 90%, Lead-acid = 50%
Inverter Efficiency
%
8599
Using defaults: DoD 90% • η 95% •
TARGET
24h Autonomy Baseline
REFERENCE
24.0h = 100%
HOURS OF ISLAND MODEON BATTERY
6.5h
NET 33.0 kW DRAW
AUTONOMY %vs 24h TARGET
27.0%
73.0% to 24h
0% — 100%
USABLE ENERGY
213.8 kWh
250 × 90% × 95%
NET LOAD
33.0 kW
Load - Solar
NIGHT COVERAGE
4.8h
usable ÷ load
BATTERY — USABLE vs TOTAL85.5% usable factor
0 kWh214 usable / 250 total250 kWh
24h CLOCK
AUTONOMY CLOCK
Filled = 6.5h coverage
Battery depletion arc
Island window
AUTONOMY TRENDISLAND HOURS vs LOAD

How runtime degrades as load rises — capped at 48h, solar input held at 12 kW.

15.715.124.433.843.252.661.971.37685.494.8104.1113.5LOAD (kW)0h15h30h48h
Island hours24h target
BATTERY HEALTHENERGY BREAKDOWN

Where your 250 kWh goes after DoD and inverter losses.

86%
USABLE SCORE
Usable Energy213.8 kWh
Efficiency Loss11.3 kWh
DoD Reserve25.0 kWh
MODERATE AUTONOMY — Partial day coverage
To reach 24h, add 676 kWh battery OR reduce net load by 24.1 kW.
Formula: Usable = Capacity × DoD × η | Hours = Usable ÷ (Load - Solar) | Verified at calculation time
Power You Can Prove — Blockchain-verifiable operator reportTeslaCoil Ventures™ • Decentralized clean energy.
    base44
    Edit with Base44